Model TR-300A 300mA radiographic X-ray unit
Application: Routine radiography; Bucky radiography.
Composition:
Control desk→high-voltage generator→high voltage cable→X-ray tube assembly←
→Radiographic table→pillar of X-ray source→ collimator
Feature:
Single bed with single tube.Rotary anode X-ray tube unit and tangential annular tubes.Single-phase full-wave rectification high-voltage generator.Power voltage(V),photograph kilovolt(kV), infinitely variable control and electric mechanism.Be equipped with the manostat for the filament of X-ray tube and space charge complemented.Photographic volume, KV, mA and S, subsection, grading and interlock protection.Adopt the digital circuit timer. Grading according to R10 priority coefficient, which is exact in time control.High-voltage primary uses the zero controlled circuit of silicon-controlled rectifier of large power .Photographic bed can move in length and breadth.10. The photographic bed, pillar and vibrating ray-filter are in a whole without top and bottom track.
Technical data:
Item | Content | Index | |
Demand of power supply | Voltage frequency | 380V/220V±10% 50Hz±0.5Hz | |
Internal resistance | 380V:0.75Ω, 220V:0.25Ω | ||
Power supply | Adjustable range | 380V±10%at380V; 220V±10%at220V being adjustable continuously | |
Radiographic | Voltage | 50-125kV being adjustable continuously | |
Current | Small focus 50mA,100mA Big focus 100,200,300mA | ||
Time | 0.05-6.3s,20grades together grading according to R10coefficient | ||
High-voltage generator | Capacity | 30kVA(instantaneous) | |
Max DC output voltage | 125kV | ||
Max DC output current | 300mA | ||
X-ray tube | Model | XD51-20.40/125 | |
Focus | Small focus:1×1mm, Big focus:2×2mm | ||
Radiographic table | Table face(L×W×H) | 2060mm×730mm×700mm | |
Moving range of table face | 800mm×230mm | ||
Ray-filter | Travel in length:690mm | ||
Grid density N28 | |||
Convergence distance of 1000mm | |||
Grid ratio R8 | |||
Pillar of X-ray tube unit | Moving in length along radiographic table | 1100mm | |
Distance to ground as moving up and down (along upright post) | 1140mm~1800mm | ||
Rotary around the center of cross arm | ±180º | ||
Rotary around the shaft line of X-ray annular tubes | -10º~60º~+120º0 | ||
Max size of cassette for radiography | 356mm×432mm(14"×17") |
TR-300A 300mA radiographic X-ray unit